| Criterion
6.3.5 High Temperature Control
Criterion
text:
Means
shall be provided to limit tank temperatures to a value not to
exceed the tank supplier's specified high temperature limit. The
pressure and temperature relief valve shall not be used for this
purpose under normal operating conditions.
Comments:
The electric water heater high temperature protection
mechanism provides a means for limiting high temperatures . The
high temperature cut-off reset button is circled in white in Figure
1.

Figure 1
Gas
water heaters incorporate a fusible link to prevent extreme temperatures.
Another
alternative available in meeting this requirement is to provide
proper system sizing. To ensure that this option is valid, the
installer must use the components specified by the manufacturer.
Proceed
to the Next Storage Subsystem Guideline
Return
to the Storage Subsystem Main Page
|