Criterion 6.4.3 Tanks

Criterion text:
Fiberglass reinforced tanks shall be used within the temperature limitations established by the tank supplier. Tanks shall be labeled to show the maximum operating pressure and temperature.

Comments:
Although the use of fiberglass tanks is not very common in current solar system installations (and SRCC certifications), if such a tank has been approved for an SRCC certified system, that specific tank will be listed on the SRCC system approval document and must be installed.

Proceed to the Next Storage Subsystem Guideline

Return to the Storage Subsystem Main Page


Return to SRCC home page