Criterion 6.1.6.11 Piping System

Criterion text:
The piping system shall be provided with valves which can be closed for the purpose of isolating the solar hot water supply system from the auxiliary hot water heater, thereby permitting operation of the auxiliary hot water heater when the solar hot water system is inoperative or being serviced.

Comments:
The installer must follow the guidelines in the SRCC approved manufacturer's installation manual. The manual will specify the types of valves required. The system schematic (Figure 1) should be used to determine the appropriate installation location of these valves. These valves will be used to close the solar system off from the backup heater so that hot water will be available to the home if the solar system is ever disabled.