| Criterion
6.1.5.4 Temperature Rating
Criterion
text:
Wiring
under insulation shall be rated for expected increased temperature
conditions.
Comments:
This criteria applies to sensor wiring placed close to
components at high temperatures.
Installers should keep sensor wiring away from direct contact
with hot piping.
If wiring is next to collector loop piping, it is better to be
adjacent to feed line piping since the return line can get reach
temperatures of 160 degrees F. These high temperatures can have
a detrimental affect on system wiring and in turn on system operation.
Figure
1 illustrates a potential problem if the sensor wiring is installed
in direct contact with the hot return line piping.

Figure 1
The
solar industry has developed flashing to accommodate both collector
feed and return line piping as well as sensor wiring - and keep
them separate. This flashing should be used. (Figure 2)
Figure 2