Criterion 6.1.1.5 Back Thermosiphon Prevention

Criterion text:
Means shall be provided to prevent undesired escape of thermal energy from storage through thermosiphoning action.

Comments:
The installer must install thermosiphon prevention components as they are indicated in the manufacturer's approved installation manual and schematic.

In the majority of systems, the manufacturer requires the use of check valves. These come in an assortment of options, including motorized (Figure 1 and 2), manual vertical (Figure 3), and horizontal swing (Figure 4). In each case, the installer must follow the manufacturers installation instructions and use the check valve provided with the system package. Installer must also make sure that the check valve is installed in the recommended location and in the proper orientation - flow and check wise.