6.1.1.6 Fluid System Sizing
Criterion
text:
Pumps,
piping, fans, ducts and other components shall be sized to carry
the heat transfer fluid at design flow rates without significant
operational impairment, erosion or corrosion. Consideration should
be given to minimizing pressure drops and vibrations. The SRCC
rating will be determined for 4.9 meter (16 ft.) head and 7.6
meter (25 ft.) pipe runs to and from the collector array.
Comments:
This system components covered in this criterion are
evaluated during SRCC system review. This evaluation includes
the type and size of piping (Figure 1) used throughout the system.
Installers must follow the manufacturer's SRCC approved installation
instructions and use only those components and materials specified.

Figure 1