| Criterion
6.2.6 Protection from Leaks
Criterion
text:
All
potable water sections of a solar water heating system shall not
leak when tested in accordance with the codes in force at the
installation site. All non-potable sections of a solar water heating
system shall be tested for leaks in accordance with the supplier's
instructions.
Comments:
The
installer must follow the instructions provided in the SRCC approved
manufacturer's installation manual - as well as excepted industry
methods for checking leaks in an installed solar system.
There
are several ways to check for leaks. Visual (Figure 1) and using
a pressure gauge are the most common.
The
system should be inspected for leaks before adding insulation
to the system piping - especially if the inspection method is
visual.

Figure 1
Proceed
to the Next Transport Subsystem Guideline
Return
to the Transport Subsystem Main Page
|